Remote Controller

Operating Instructions Before operating the unit, please read this manual thoroughly and retain it for future reference.

RM-IP500

© 2017 Sony Corporation

Operating the Camera Setup Menu from the Unit (Camera Menu Operation Mode) ...................... 35 Buttons and knobs used for camera menu operations ....................................................... 35 Setting Specific Functions using Shortcuts (FUNCTION Menu) ........................................... 37 Buttons and knobs used for FUNCTION menu operations ....................................................... 37 Operation using IRIS, GAIN, and SHUTTER buttons ........................................................... 37 Operation using ASSIGN 4, ASSIGN 5, and ASSIGN 6 ...................................................... 38 Checking Camera Settings Status (Status Display) ................................................................ 38 Restoring Factory Default Settings ................... 39 Default values .................................................. 39 Function of Buttons/Knobs in Each Block by Camera Model ..................................................... 41

Table of Contents Introduction Using This Manual ................................................4 Features ..................................................................4 Location and Function of Parts ............................5 Top .....................................................................5 Rear ..................................................................10 Side / front ........................................................11 Menu Operations .................................................12 Basic menu operations .....................................12

Getting Started Connections ..........................................................14 VISCA over IP (LAN) connection ...................14 VISCA RS-422 (serial) connection ..................21 Connection with a video switcher ....................24 Using a Setup PC .................................................25 Accessing a remote controller ..........................25 Saving configuration data on a PC (Backup) ...25 Loading a saved configuration file into the unit or another remote controller (Restore) ....26 About the RM-IP Setup Tool ...........................26

RM Menu List OPERATION ....................................................... 43 EXPOSURE ..................................................... 43 WHITE ............................................................ 43 BLACK ............................................................ 44 DETAIL ........................................................... 44 KNEE ............................................................... 44 MATRIX .......................................................... 44 PRESET ........................................................... 44 OPERATION menu support by camera model ............................................................. 45 CONFIG .............................................................. 46 RM SETUP ...................................................... 46 SW ASSIGN .................................................... 46 DIRECTION .................................................... 46 GPI I/O ............................................................ 47 LAN ................................................................. 48 SERIAL ........................................................... 48 CONTROL I/F ................................................. 48 AUTO IP SETUP ................................................ 48 SETUP IP ........................................................ 48 ASSIGN CAM ................................................. 48 CLEAR TABLE ............................................... 48 SWAP CAM .................................................... 48 CAMERA TABLE ........................................... 48 MAINTENANCE ................................................ 49 MODEL INFO ................................................. 49 UPDATE MODE ............................................. 49 RESET ............................................................. 49

Operations Turning on the Power ..........................................27 Selecting a Camera ..............................................27 Selecting a camera when using LAN connection ......................................................27 Selecting a camera when using serial connection ......................................................28 About the color of camera buttons ...................28 About the tally lamp indicators ........................28 Operating a Camera ............................................29 Pan and tilt control ...........................................29 Zoom control ....................................................30 Adjusting a Camera ............................................31 Adjusting the focus ..........................................31 Adjusting the brightness ...................................31 Backlight compensation ...................................32 Flicker compensation .......................................32 Adjusting the white balance .............................32 Adjusting the black balance .............................33 Storing the Camera Status (Preset Function) ...34 Recalling stored status .....................................34 Changing the speed of movement between positions .........................................................34

Appendix Troubleshooting ................................................... 50 Specifications ....................................................... 51 Dimensions ...................................................... 51

2

Pin assignments ................................................52 TALLY/CONTACT connector input connection example ..........................................................53 TALLY/CONTACT connector output connection example ..........................................................53 Input waveform of TALLY/CONTACT connector ........................................................53 License ..................................................................54

• Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/ or other countries. • Intel and Core are registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. All other company and product names are trademarks or registered trademarks of the respective companies or their respective makers. Trademarked items are not indicated by ® or ™ symbols in this manual.

Data and security • SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND RESULTING FROM A FAILURE TO IMPLEMENT PROPER SECURITY MEASURES ON TRANSMISSION DEVICES, UNAVOIDABLE DATA LEAKS RESULTING FROM TRANSMISSION SPECIFICATIONS, OR SECURITY PROBLEMS OF ANY KIND. • Depending on the operating environment, unauthorized third parties on the network may be able to access the unit. When connecting the unit to the network, be sure to confirm that the network is protected securely. • Do not browse any other website in the Web browser while making settings or after making settings. Since the login status remains in the Web browser, close the Web browser when you complete the settings to prevent unauthorized third parties from using the unit or harmful programs from running.

3

Introduction

Features

Safety Regulations (Supplied)

This unit is a remote controller that provides the full functionality and operability of Sony PTZ cameras.

Describes the important points for safe use of the unit. Be sure to read it.

Simple system construction The unit can be used to control up to 100 cameras connected via LAN connection using switching hubs. You can build a system, using the setup functions of the unit, to set the IP address and camera number of multiple cameras in a single step, without using a setup PC.

Operating Instructions (This document/ Web) These operating instructions describe the names of the various parts of the unit, installation, connection, and operation methods.

Functional design The buttons and knobs of the control panel are grouped by type of operation for easy operation. For example, the buttons and knobs for making color adjustments on a camera are grouped together in the color adjustment block.

Using This Manual The Operating Instructions is designed to be read on a computer display. The content you need to know in order to use the unit is described here. Read it before you operate the unit.

Compact size The unit has a compact size for mounting on a desktop. It can also be mounted in a console desk. Flexible camera operation for various use cases You can adjust the pan, tilt, and zoom of the camera image with one hand using a joystick. The zoom operation can also be controlled using a zoom lever, enabling detailed camera control using both hands. The speed of pan, tilt, and zoom can also be adjusted using a speed adjustment knob.

Jumping to a related page When you read the instructions on a computer display and click on the related part of the relevant page that is being displayed, you jump to the related page. Relevant pages can be searched easily.

Software display examples

Preset memory function You can save camera settings, such as pan/tilt/zoom positions and other camera adjustment settings, in the memory of the camera. The stored settings can be recalled and applied to the camera by pressing a preset number button assigned when storing settings.

The software displays described in this manual are explanatory examples. Note that some displays may be different from the ones that actually appear.

Printing the Operating Instructions Depending on your system, certain displays or illustrations in the Operating Instructions, when printed out, may differ from those that appear on your screen.

Simple operation of various camera adjustments Using the buttons on the unit, you can quickly control various camera functions, such as auto focusing, onepush auto focus, AE (Auto Exposure) function, onepush auto white balance, and backlight compensation, without having to access the camera menu.

Terminology in this document The RM-IP500 is referred to as the “unit” or “remote controller” in this document.

4

Location and Function of Parts The functions controlled by the buttons and knobs vary depending on the target camera to control. For details, see “Function of Buttons/Knobs in Each Block by Camera Model” (page 41).

Top Color adjustment block (page 5)

Lens control block (page 7)

Menu control block (page 6)

Camera selection block (page 7)

Preset memory control block (page 8)

Joystick control block (page 9)

Color adjustment block Use to perform color adjustments on a camera. Select the target camera to adjust the color. The color adjustment block is enabled when the 7 ACTIVE button is lit. For details about selecting the target camera, see “Selecting a Camera” (page 27).

4

3 2-b 2-a 1-c 1-b 1-a

5

5

6

7

8

H ASSIGN 1 button, ASSIGN 2 button, ASSIGN 3 button Executes functions assigned to each button on the target camera. In this version, the following functions have been assigned, and cannot be changed.

A 1-a R-BLACK knob 1-b B-BLACK knob 1-c MASTER BLACK knob Adjusts the R black, B black, and master black of the target camera. For details, see “Adjusting the black balance” (page 33).

Button name Assigned function

B 2-a R-WHITE knob 2-b B-WHITE knob Sets the R gain and B gain of the target camera, and adjusts the white balance. For details, see “Adjusting the white balance” (page 32). C BARS button Toggles the color bars output of the target camera on/off. When the button is turned on (button is lit yellow), color bars output is turned on. When the button is turned off (button is not lit), color bars are not output.

ASSIGN 1

Perform backlight compensation on the target camera. For details, see “Backlight compensation” (page 32).

ASSIGN 2

Perform flicker compensation on the target camera. For details, see “Flicker compensation” (page 32).

ASSIGN 3

Display the iris, gain, shutter speed, and zoom position settings of the target camera on the LCD panel. For details, see “Checking Camera Settings Status (Status Display)” (page 38).

Menu control block Comprises buttons and knobs you use to set and execute functions, and to change settings on the target camera using menu operations. For details about menu operations, see “Menu Operations” (page 12).

D CAM POWER button Toggles the power supply of the target camera on/ off (standby). When the button is turned on (button is lit green), the target camera is turned on. When the button is turned off (button is not lit), the target camera is turned off (standby).

2

Note

3

When controlling more than one camera, the camera on/off operation is determined by the CONFIG >RM SETUP >CAM POWER setting in the RM menu. For details, see “CAM POWER” (page 46).

4 5 1

E O.P.AWB (one-push auto white balance) button Executes one-push auto white balance adjustment on the target camera. For details, see “To adjust the white balance automatically” (page 32).

6 7

A FUNCTION menu buttons When a button is pressed, the item and setting of the function assigned to the button is displayed on the LCD panel, and the setting can be changed using the VALUE knob. The IRIS, GAIN, and SHUTTER button operations are enabled when the buttons are lit blue. For details about operation, see “Setting Specific Functions using Shortcuts (FUNCTION Menu)” (page 37). IRIS button: Press this button to display the iris value settings screen for the camera on the LCD panel.

F O.P.ABB (one-push auto black balance) button Executes one-push auto black balance adjustment on the target camera. For details, see “To adjust the black balance automatically” (page 33). G ACTIVE button Enables/disables the color adjustment block. When the button is turned on (button is lit), the color adjustment block becomes enabled. When the button is turned off (button is not lit), the color adjustment block becomes disabled.

6

G CAM MENU button Press and hold this button to display the setup menu of the camera on the monitor output of the camera. Nothing is displayed on the LCD panel of the unit. For details about operation, see “Operating the Camera Setup Menu from the Unit (Camera Menu Operation Mode)” (page 35).

GAIN button: Press this button to display the gain value settings screen for the camera on the LCD panel. SHUTTER button: Press this button to display the shutter speed value settings screen for the camera on the LCD panel. ASSIGN 4 button, ASSIGN 5 button, ASSIGN 6 button: Press these buttons to display the corresponding setup item and setting of the function assigned to each button on the LCD panel. In this version, the following functions have been assigned, and cannot be changed.

Camera selection block Use to select the target camera to control. When using LAN connection, the unit can control up to 100 cameras. When using serial connection, the unit can control up to 7 cameras.

Button name Assigned menu item ASSIGN 4

Sets DETAIL LEVEL on the target camera.

ASSIGN 5

Sets KNEE POINT on the target camera.

ASSIGN 6

Sets AE LEVEL on the target camera.

2

For details about menu operations, see “Menu Operations” (page 12). B LCD panel Displays the RM menu, FUNCTION menu, and preset memory numbers. • For details about menu operations, see “Menu Operations” (page 12). • For details about the RM menu, see “RM Menu List” (page 43). • For details about the FUNCTION menu, see “Setting Specific Functions using Shortcuts (FUNCTION Menu)” (page 37). • For details about preset numbers, see “Storing the Camera Status (Preset Function)” (page 34).

1

A CAMERA 1 to CAMERA 10 buttons Selects the target camera from within a group. For details about selecting the target camera, see “Selecting a Camera” (page 27). B GROUP LEFT button, group number display, GROUP RIGHT button Select the target camera group using the GROUP LEFT button and GROUP RIGHT button. The number of the selected group is displayed in the group number display. Group numbers are used with LAN connections. For details about selecting a group, see “Selecting a Camera” (page 27).

C SELECT knob and button Use to select menu items. For details about menu operations, see “Menu Operations” (page 12). D VALUE knob and button Use to select the settings of menu items. For details about menu operations, see “Menu Operations” (page 12).

Lens control block Use to control the lens (adjustment and settings) of the target camera. The lens control block is enabled when the 5 ACTIVE button is lit. Note that the ZOOM SPEED knob is always enabled.

E CANCEL button Use to move from a lower level to a higher level in the hierarchy for menu items that have a multi-level hierarchy. F RM MENU button Press this button to display the setup menu of the unit on the LCD panel. For details about menu operations, see “Menu Operations” (page 12).

7

G AUTO FOCUS mode button Switches between automatic (button is lit) and manual (button is not lit) focus adjustment mode on the target camera. For details, see “To adjust the focus automatically” (page 31).

3 4 5 2

1

6

H O.P.A.F (one-push auto focus) button Press during manual focus adjustment mode to execute one-push auto adjustment. For details, see “One-push auto focus during manual focus adjustment” (page 31).

7 8

I FOCUS adjustment knob Adjusts the focus of the target camera manually. For details, see “To adjust the focus manually” (page 31).

9

Preset memory control block A IRIS knob Adjusts the iris of the target camera. For details, see “To adjust the exposure manually” (page 31).

Use to execute the Preset function for storing and recalling camera status (such as pan, tilt, zoom position settings) in internal memory on the camera. The preset memory control block is enabled when the 4 ACTIVE button is lit.

B AE button Switches the exposure mode of the target camera. When the button is turned on (button is lit), auto adjustment mode is selected. When the button is turned off (button is not lit), the exposure mode set in the RM menu is selected. For details, see “To adjust the exposure automatically” (page 31).

Note

The number of presets varies depending on the model and firmware version of the camera. For details, refer to the Operating Instructions supplied with the camera. 2

3

4

C ZOOM SPEED knob Sets the speed of zoom operations. For details, see “To control the zoom using the ZOOM lever on the lens control block” (page 30). D ZOOM lever Controls the zoom operation of the target camera. For details, see “To control the zoom using the ZOOM lever on the lens control block” (page 30).

1 5 6

E ACTIVE button Enables/disables the lens control block. When the button is pressed, turning it on (button is lit), the lens control block becomes enabled. When the button is turned off (button is not lit), the lens control block becomes disabled.

A PRESET 1 button to PRESET 10/0 button Use to enter the number (preset number) for registering and recalling a preset camera status. For details, see “Storing the Camera Status (Preset Function)” (page 34).

F FOCUS SPEED knob Sets the focus speed when adjusting the focus manually. For details, see “To adjust the focus manually” (page 31).

8

B DIRECT RECALL button Recalls a preset stored in the target camera. Direct recall mode is enabled when the button is lit. Press PRESET 1 to PRESET 10/0 to recall the stored settings immediately. For details, see “Storing the Camera Status (Preset Function)” (page 34).

Controls the pan, tilt, and zoom operation of the target camera. Pan/tilt: Incline the joystick left/right to rotate the camera counterclockwise/clockwise (pan left/ right), incline the joystick forward/backward to tilt the camera up/down. The panning/tilting speed changes according to the angle at which you incline the joystick. Movement stops when the joystick returns to the center position (position the joystick returns to after removing your hand). Zoom: Turn the ZOOM ring on the upper part of the joystick clockwise to make the subject larger (zoom in). Turn it counterclockwise to make the subject smaller (zoom out).

C CLEAR button Clears the currently entered preset number. D ACTIVE button Enables/disables operation of the preset memory control block. When the button is turned on (button is lit), the preset memory control block becomes enabled. When the button is turned off (button is not lit), the preset memory control block becomes disabled.

A-a Joystick button Press and hold to return the orientation of the camera to face the front.

E STORE button Stores the camera status in the internal memory of the camera for the specified preset number. For details, see “Storing the Camera Status (Preset Function)” (page 34).

A-b ZOOM ring Controls the zoom. For details, see “To control the zoom using the ZOOM ring on the top of the joystick” (page 30). B PAN-TILT SPEED knob Adjusts the speed of pan/tilt operations in response to the joystick. For details, see “To adjust the pan/tilt speed” (page 29).

F RECALL button Recalls a preset stored in the target camera. For details, see “Recalling stored status” (page 34).

Joystick control block Use to control the pan, tilt, and zoom of the target camera using a joystick. The joystick control block is enabled when the 4 ACTIVE button is lit. Select the target camera to control the pan, tilt, and zoom using a joystick. For details about camera pan, tilt, and zoom operations, see “Pan and tilt control” (page 29) and “Zoom control” (page 30).

2

3

C P/T RST (pan/tilt reset) button Press the button to reset the pan/tilt position of the target camera. D ACTIVE button Enables/disables operation of the joystick control block. When the button is turned on (button is lit), operation of the joystick control block becomes enabled. When the button is turned off (button is not lit), operation of the joystick control block becomes disabled.

4

1

1 1

A Joystick

9

2 Connect an AC adapter.

Rear

Cord clamper

9

9 Cord of the AC adapter

12

A B

3

4

5 6

3 Thread the cord of the AC power adapter through the cord clamper, then close the lock.

7 8

Anti-theft wire attachment point Attach a wire to prevent theft. Ground connection

C GPI I/O connector Used as a tally input from an external device or as a contact output connector of the selected camera number.

H Power switch Turns the power ^ (on) and 1 (off). Note

D LAN (network) connector (RJ-45) Use for LAN connection. Connect a LAN hub (10BASE-T/100BASE-TX) using a LAN cable (category 5 or higher). When a link is established, the green indicator lights, and it blinks during communication. For 100BASE-TX connections, the yellow indicator lights.

When the unit is mounted in a console desk, turn the power on/off using the main power supply of the console desk. I Screw holes Mounting points available for use when not mounting the unit on a flat surface. Screw holes are provided on all sides, with the screw holes on the front, left, and right sides protected by covers (six locations).

Notes

• For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port. • When you connect the LAN cable of the unit to peripheral device, use a shielded-type cable to prevent malfunction due to radiation noise. E VISCA RS-422 connector (RJ-45) Used for VISCA RS-422 serial connection. F

12V! (DC power supply input) connector Connect to an AC power adapter.

G Cord clamper Clamp the cord of the AC power adapter to prevent the cord from being pulled out of the unit. 1 Release the lock of the cord clamper.

10

Removing the screw hole protective covers

Side / front

1

Bend the tip of a thin rod about 2 mm, and insert it into the hole of the screw hole protective cover. Use a paper clip or other object with a diameter of about 1 mm.

2

Pull the screw hole protective covers straight out.

1

1

1

1

2

A Screw hole protective covers When mounting the unit on other than a flat surface, remove the screw hole protective covers and secure the unit in place with screws. There are a total of six covers on the front, left, and right sides. Note

B Ratings label (bottom) Displays the model name and electrical ratings information.

• Use standard size screws with the following dimensions. M3 screw

IMPORTANT

4

The nameplate is located on the bottom. 4=6 mm to 10 mm

• Do not overtighten the screws. Overtightening the screws may damage the unit. • Store the removed screw hole protective covers in a safe location. • Using screws other than 6 mm to 10 mm may result in faulty installation or damage to the interior of the machine, resulting in malfunction.

11

For details, see “Setting Specific Functions using Shortcuts (FUNCTION Menu)” (page 37).

Menu Operations The menu control block is used to configure the device settings and camera settings.

Basic menu operations Buttons and knobs used for RM menu operations Operation

Buttons and knobs used OPERATION menu

1

CONFIG, AUTO IP SETUP, or MAINTENANCE menu

Display the top Press the RM MENU button. menu.

2 3

One of the three menus (RM menu, camera menu, or FUNCTION menu) is always selected. When the RM menu or FUNCTION menu is selected, the menu items and settings are displayed on the LCD panel. When the camera menu is selected, nothing is displayed on the LCD panel.

Select a top menu item.

Turn the SELECT knob.

Confirm the menu item selection.

Press the SELECT button.

Select a setup menu item.

Turn the SELECT knob.

Confirm the setup menu item selection.

Press the SELECT button.

Select a setup Turn the SELECT knob. menu sub item. Change the Turn the VALUE knob. setting of the setup menu sub item.

Note

Except for the OPERATION menu, return to the top menu when operating a camera. If a lower-level menu is displayed, cameras cannot be operated. A RM menu This menu is used to configure picture quality adjustments and compensation functions on target cameras, configure the unit, execute/configure auto assign functions on cameras, and for performing configuration from a connected setup PC. When the RM menu button is turned on, RM menu setup mode is invoked and the top menu is displayed on the LCD panel. For details, see “RM Menu List” (page 43).

Confirm the changed setting.

Confirmation not required.

Press the VALUE button.*1

Save settings.

Saved on the camera using the camera preset memory function.*3

Save on the unit.

Go back one level in the menu.

Press the CANCEL button.

Press the CANCEL button.*2

*1 A confirmation message appears for settings that display an EXEC item. *2 If the CANCEL button is pressed before attempting to save, the menu display goes back one level and restores the existing setting. *3 For details about items saved with a preset number, refer to the operating instructions of each camera.

B Camera menu Turns the superimposed output of the camera setup menu on the camera image on/off. When turned on, operation of the setup menu on the camera using the knobs and buttons on the menu control block and the joystick is enabled. For details, see “Operating the Camera Setup Menu from the Unit (Camera Menu Operation Mode)” (page 35). C FUNCTION menu This menu is used to configure functions assigned to buttons using shortcuts.

12

Typical RM menu operation

The cursor moves up/down as the SELECT knob is turned.

7

Turn the VALUE knob to select the setting.

2~7 1

1 2

Cursor

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

Selected setting

To configure items in other menus Press the CANCEL button to return to the parent item in the menu, and then use the same procedure.

Turn the SELECT knob to move the cursor to the desired item to set. The cursor moves up/down as the SELECT knob is turned.

To save a setting in the unit Press the VALUE button after adjusting the setting.

Cursor

3

Press the SELECT button. The menu for the selected item appears.

4

Turn the SELECT knob to move the cursor to the desired setup menu item. The cursor moves up/down as the SELECT knob is turned.

Cursor

5

Press the SELECT button. The selected menu item and its setup items appear.

6

Turn the SELECT knob to move the cursor to the desired item.

13

VISCA over IP (LAN) connection

Getting Started

VISCA over IP (LAN) connection is configured using the following sequence. Setting the IP address of the unit (page 14)

Connections

m

You can connect the unit to cameras using VISCA over IP (LAN) connection or VISCA RS-422 (serial) connection.

Connecting remote controllers, cameras, and setup PC using LAN connection (page 16)

m The connection method that is used is displayed at the bottom of the CONFIG menu item in the RM menu.

Assigning cameras (page 17) • Assignment using AUTO IP SETUP >SETUP IP (page 17) • Assignment using AUTO IP SETUP >ASSIGN CAM (page 18)

VISCA over IP (LAN) connection

Setting the IP address of the unit Before connection, set the IP address of the unit. The setting is configured using CONFIG >LAN in the RM menu.

VISCA RS-422 (serial) connection

2~11 1

1 • For details about VISCA over IP (LAN) connection, see “VISCA over IP (LAN) connection” (page 14). • For details about VISCA RS-422 (serial) connection, see “VISCA RS-422 (serial) connection” (page 21).

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

2

Turn the SELECT knob to move the cursor to CONFIG.

For details about connections, refer to the operating instructions supplied with the camera.

3

Press the SELECT button. The CONFIG menu appears.

4

Turn the SELECT knob to move the cursor to LAN, and press the SELECT button.

14

The LAN menu appears. Upon rebooting, the IP address setting is completed.

The MAC address is displayed at the bottom.

5

Turn the SELECT knob to move the cursor to IP.

6

Set the IP address using the SELECT knob and VALUE knob/button. The default setting is 192.168.0.10. 1 Turn the SELECT knob clockwise to move the cursor to the first three digits (for example, 192). IP:p192. 168. 0. 10 2 Turn the VALUE knob to set the value. Turning clockwise increases the value, and turning counterclockwise decreases the value. 3 Turn the SELECT knob to move to the next number and repeat step 2 to set the other numbers.

7

Set SM (subnet mask) and GW (default gateway address) in the same way as described in steps 5 and 6.

8

When finished making all settings, move the cursor to APPLY.

9

Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. The following message appears, prompting you to reboot the unit.

10 Turn the SELECT knob to move the cursor to CONFIRM.

11 Turn the VALUE knob to change NO to YES, then press the VALUE button. The unit reboots automatically.

15

Connecting remote controllers, cameras, and setup PC using LAN connection Connection example

BRC-H900 1 2 3

1 2 3 4 5 6 7 8 9

R

IR SELECT

RM-IP500

VISCA RS-422

OFF

ON

HD

SD

RGB/COMPONENT

75

IN VISCA RS-232 OUT EXT SYNC IN

BRBK-IP10 IP control card*3

VIDEO

S VIDEO

1

BRBK-IP10

LAN

DC IN 12V

SDI OUT

2

DATA MIX OFF ON HD

SDI OUT

SD

BRC-X1000, BRC-H800 MODE

LAN

RS-232C

VISCA

RS-422

! IR SELECT

CAMERA SETUP

1 2 3

Switching hub

RM-IP10

SYSTEM SELECT

IN VISCA RS - 422 OUT

Video switcher*1

12V

LAN OSD ON OFF

HDMI OUT

MONITOR OUT SDI 1 SDI 2

LINE OUT SDI 1 SDI 2

EXT SYNC IN TERMINATION ON OFF

SRG-360SHE

MIC

RAUD RATE

Setup PC

R

VISCA RS-422

IR SELECT

L (PLUG IN POWER)

SYSTEM SELECT

HDMI OUT

SDI OUT

LAN

Video monitor

Remote control signal: LAN cable (category 5 or higher) Tally/contact signal: Connection cable with D-sub 15-pin connectors*2 Video signal: HDMI cable*2 Video signal: Connection cable with BNC connectors Signal flow

*1 For an example connection with a video switcher, see “Connection with a video switcher” (page 24). *2 Use a connection cable designed for the switcher being used. For the specifications of the GPI I/O connector of the unit, see “Pin assignments” (page 52). *3 To connect the BRC-H900 using a LAN connection, a BRBK-IP10 IP control card must be installed. In addition, use an IP control card with firmware version 2.1 or later.

1

Connect the LAN connector of the units and LAN connector of the cameras using LAN cables. You can connect up to 100 cameras and five remote controllers on the same network.

2

To configure setting of the unit and cameras using setup software, connect a PC to the same network. • Use shielded-type LAN cables to prevent malfunction that may result from radiation noise. • Use a LAN cable (category 5 or higher).

• Connect the cameras, remote controllers, and PC via switching hubs (10BASE-T or 100BASETX). Use on a network with significant packet loss or delay may cause a malfunction. Use a high-quality network. • Do not mix 10BASE-T and 100BASE-TX in the network. • The IP address of the unit is set to 192.168.0.10, and the IP address of a camera and BRBK-IP10

16

IP control card is set to 192.168.0.100 by factory default. • Connecting stackable switching hubs in up to 2tier configuration is recommended to avoid network delay.

3~

Notes

2

• Do not connect more than 100 cameras, five remote controllers, and one setup PC across all networks, even if controlling a camera that is on a network of a different segment via a router. If you connect more devices than this, problems may occur, such as control delays or cameras are operated incorrectly due to IP address duplication. • If you perform the setup from multiple PCs, the settings may not be made correctly. Perform the setup from one PC. • Set the setup PC so that only the network that you use is enabled. • Do not connect cameras and remote controllers to a public network.

3

Connect the cameras and remote controllers to AC outlets using AC adapters and AC power cords. The cameras pan/tilt automatically when power is turned on.

Assigning cameras Link the camera numbers, used for operating cameras from the unit, with the cameras on the network. This is called camera assignment. A list of the assigned cameras is saved in the unit as a camera table. Camera numbers are sequential in each group, and are selected using the GROUP buttons and CAMERA number buttons of the camera selection block.

1

Check that the assigned camera is connected to the network, and that the camera power is turned on.

2

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

3

Turn the SELECT knob to move the cursor to AUTO IP SETUP.

4

Press the SELECT button. The AUTO IP SETUP menu appears.

5

Turn the SELECT knob to select SETUP IP or ASSIGN CAM, and press the SELECT button. Select one of the following methods, depending on the type of camera assignment. • For connections on a new network: “Assignment using AUTO IP SETUP >SETUP IP” (page 17) • For adding an assignment to an existing network: “Assignment using AUTO IP SETUP >ASSIGN CAM” (page 18) Assignment using AUTO IP SETUP >SETUP IP This method detects cameras on the network, and automatically assigns the IP address setting and camera number for unregistered cameras. Use this method when constructing a new network. With this method, you specify the range of IP addresses assigned to cameras by entering the start address in [FROM] and the end address in [TO]. Set the range of IP addresses for assignment so that they are in the same segment as the remote controller.

Camera assignments are performed using AUTO IP SETUP >SETUP IP or AUTO IP SETUP >ASSIGN CAM in the RM menu. Note

Only cameras that are on the same segment as the remote controller can be assigned using AUTO IP SETUP. Use the setup software to assign cameras on different segments.

Note

The same IP address as a remote controller cannot be set. The subnet mask (SM) and gateway address (GW) of the camera are assigned the same settings as the remote controller.

17

qs Check the camera assignment result using AUTO IP SETUP >CAMERA TABLE in the RM menu. For details about displaying CAMERA TABLE, see “To check the camera table” (page 20). Assignment using AUTO IP SETUP >ASSIGN CAM This method is used to assign camera numbers to cameras that already have a configured IP address. With this method, you can specify the group number and camera number of the camera selection button from which to start assignments. For details about the group number and camera number, see “Selecting a Camera” (page 27).

1 Turn the SELECT knob to move the cursor to IP under [FROM]. 2 Set the start value of the IP addresses to assign to newly registered cameras. Turn the SELECT knob clockwise to move the cursor to the first three digits (for example, 192). IP: p192. 168. 0. 100

Note

Only cameras within the same segment can be assigned.

3 Turn the VALUE knob to set the value. Turning clockwise increases the value, and turning counterclockwise decreases the value. 4 Turn the SELECT knob to move to the next number and repeat step 3 to set the other numbers. 5 Turn the SELECT knob to move the cursor to IP under [TO]. 6 Set the end value of the IP addresses to assign to newly registered cameras. Turn the SELECT knob clockwise to move the cursor to the first three digits (for example, 192). IP:p192. 168. 0. 199

1 Turn the SELECT knob to move the cursor to GROUP NUM. Set the group number for which to begin assignment. 2 Turn the VALUE knob to set the value. Turning clockwise increases the value, and turning counterclockwise decreases the value. 3 Turn the SELECT knob to move the cursor to CAMERA NUM. Set the camera number for which to begin assignment. 4 Turn the VALUE knob to set the value. Turning clockwise increases the value, and turning counterclockwise decreases the value. 5 When finished making all settings, turn the SELECT knob to move the cursor to KEEP IP. 6 Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. A confirmation message appears.

7 Turn the VALUE knob to set the value. Turning clockwise increases the value, and turning counterclockwise decreases the value. 8 Turn the SELECT knob to move to the next number and repeat step 7 to set the other numbers. 9 When finished making all settings, turn the SELECT knob to move the cursor to SETUP IP. 0 Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. A confirmation message appears.

qa Turn the VALUE knob to change NO to YES, then press the VALUE button.

18

6

Turn the VALUE knob to change NO to YES, then press the VALUE button.

To swap camera numbers You can change the camera numbers after IP addresses have been configured automatically.

7 Turn the VALUE knob to change NO to YES, then press the VALUE button.

1

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

2

Turn the SELECT knob to move the cursor to AUTO IP SETUP.

3

Press the SELECT button. The AUTO IP SETUP menu appears.

4

Turn the SELECT knob to select SWAP CAM, and press the SELECT button. The SWAP CAM menu appears.

To add cameras Perform the configuration again using AUTO IP SETUP >SETUP IP or AUTO IP SETUP >ASSIGN CAM. Assigned cameras are added to the bottom of the camera table. For details, see “Assignment using AUTO IP SETUP >SETUP IP” (page 17) or “Assignment using AUTO IP SETUP >ASSIGN CAM” (page 18).

To clear the camera table You can clear all the camera information stored in the camera table. Note

The camera table cannot be restored once it has been cleared.

1 2

5

Turn the SELECT knob to move the cursor to AUTO IP SETUP.

Turn the SELECT knob to move the cursor to CAMERA A.

6

Turn the VALUE knob to change the camera group number and the camera number of the camera to swap.

3

Press the SELECT button. The AUTO IP SETUP menu appears.

4

Turn the SELECT knob to select CLEAR TABLE, and press the SELECT button. The CLEAR TABLE menu appears.

5

This screen is used to swap the camera information of CAMERA A and CAMERA B.

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

pCAMERA A

: 01-01 Camera number Group number

The IP address and MAC address of the corresponding camera are displayed in IP and MAC, respectively.

Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. A confirmation message appears.

19

7

Turn the SELECT knob to move the cursor to CAMERA B.

8

Enter the camera group number and the camera number of the camera to swap using the same procedure for CAMERA A.

9

LOWER display

Turn the SELECT knob to move the cursor to SWAP A<=>B. pSWAP A<=>B : NOT EXEC


10 Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. A confirmation message appears.

M O M 1 2 3 4 5

ER UP I :1 :1 :1 :1 :1

A N 9 9 9 9 9

N F 2 2 2 2 2

UPPER display

TABLE> UM : 01-LOWER O : IP ADD .168. 0.100 .168. 0.101 .168. 0.102 .168. 0.103 .168. 0.104


M O M 6 7 8 9 0

ER UP I :1 :1 :1 :1 :1

A N 9 9 9 9 9

N F 2 2 2 2 2

TABLE> UM : 01-UPPER O : IP ADD .168. 0.105 .168. 0.106 .168. 0.107 .168. 0.108 .168. 0.109

You can turn the SELECT knob to move the cursor to CAM INFO, then turn the VALUE knob to switch the camera information between IP ADD and MAC ADD display. pCAM INFO

: IP ADD IP ADD or MAC ADD

In IP ADD display, the IP addresses of the cameras are displayed. In MAC ADD display, the MAC addresses of the cameras are displayed.

11 Turn the VALUE knob to change NO to YES, then press the VALUE button.

12 Check the result using AUTO IP SETUP >CAMERA TABLE in the RM menu.

MAC address display

To check the camera table You can check all the camera information in the camera table.

1

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

2

Turn the SELECT knob to move the cursor to AUTO IP SETUP.

3

Press the SELECT button. The AUTO IP SETUP menu appears.

4

Turn the SELECT knob to select CAMERA TABLE, and press the SELECT button. The CAMERA TABLE menu appears. The camera information for cameras 1 to 5 in group 1 are displayed on the screen. You can check the camera information for other cameras not displayed by turning the VALUE knob. pGROUP NUM

: 01-LOWER LOWER or UPPER Group number

The camera information for cameras 01 to 05 in a group are displayed when LOWER is selected. The camera information for cameras 06 to 10 in a group are displayed when UPPER is selected.

20

VISCA RS-422 (serial) connection You can connect multiple cameras in a serial connection using the VISCA RS-422 connectors. In a serial connection, a remote controller can control up to seven cameras. These cables support connection at distances of up to 1.2 km (3,937 feet). Use a LAN straight cable for RS-422 connection using the RJ-45 connector.

Connecting remote controllers and cameras using serial connection Connection example

For connection of a single camera to a single remote controller

Camera with RJ-45 connector

MIC

RAUD RATE R

VISCA RS-422

IR SELECT

L (PLUG IN POWER)

SYSTEM SELECT

HDMI OUT

SDI OUT

LAN

RM-IP500

For connection of multiple cameras to a single remote controller

RM-IP500

CAMERA SETUP

ON

1 2 3 1 2 3 4 5 6 7 8

IN VISCA RS - 422 OUT

1 2 3

1 2 3 4 5 6 7 8 9

SYSTEM SELECT

OSD

IN VISCA RS - 422 OUT

VISCA RS-422

OFF

ON

LINE OUT SDI 1 SDI 2

HD

SD

RGB/COMPONENT

75

SYSTEM SELECT

IN VISCA RS - 422 OUT

HDMI OUT

EXT SYNC IN TERMINATION

MONITOR OUT SDI 1 SDI 2

LINE OUT SDI 1 SDI 2

VIDEO

S VIDEO

DC IN 12V

SDI OUT

HDMI OUT

EXT SYNC IN

1

BRBK-IP10

TERMINATION

2

DATA MIX OFF ON

ON OFF

MONITOR OUT SDI 1 SDI 2

LINE OUT SDI 1 SDI 2

EXT SYNC IN TERMINATION ON OFF

LAN

IN

12V

ON OFF

ON OFF

OUT

LAN OSD

ON OFF

IN VISCA RS-232 OUT EXT SYNC IN MONITOR OUT SDI 1 SDI 2

CAMERA SETUP

1 2 3

1 2 3 4 5 6 7 8

12V

LAN OSD

ON OFF

HDMI OUT

IR SELECT

R

IR SELECT 1 2 3 4 5 6 7 8

12V

LAN

Camera with RJ-45 connector

ON

IR SELECT

CAMERA SETUP

1 2 3

ON

IR SELECT

SYSTEM SELECT

Camera with 9-pin connector

Camera with RJ-45 connector

Camera with RJ-45 connector

IN

SDI OUT

HD

SD

OUT

IN

Remote control signal: LAN straight cable (category 5 or higher)

Up to seven cameras

Note

When connecting an SRG-360SHE in a serial connection, only one SRG-360SHE camera can be connected to a single remote controller. To connect multiple SRG-360SHE cameras or to mix with other model cameras, use the connection described in “VISCA over IP (LAN) connection” (page 14).

21

VISCA RS-422 connection diagram example

3rd to 7th camera Camera with RJ-45 connector VISCA RS-422 IN connector (RJ-45) 1 2 3 4 5 6 7 8

TXD_INTXD_IN+ RXD_IN GND GND RXD_IN+ NC NC

2nd camera Camera with RJ-45 connector VISCA RS-422 OUT connector (RJ-45) 1 2 3 4 5 6 7 8

RXD_OUT RXD_OUT+ TXD_OUTGND GND TXD_OUT+ NC NC

VISCA RS-422 IN connector (RJ-45) 1 2 3 4 5 6 7 8

TXD_INTXD_IN+ RXD_IN GND GND RXD_IN + NC NC

1st camera Camera with 9-pin connector VISCA RS-422 connector (connector block) 1 2 3 4 5 6 7 8 9

RM-IP500 Remote Controller VISCA RS-422 connector (RJ-45) 1 2 3 4 5 6 7 8

RXD_OUT RXD_OUT+ TXD_OUTGND GND TXD_OUT+ NC NC

NC = No connection (not used)

22

RXD_OUT RXD_OUT+ TXD_OUTTXD_OUT+ GND RXD_IN RXD_IN+ TXD_INTXD_IN+

Configuring a serial connection

connection or changing the baud rate, prompting you to reboot the unit.

After cameras are connected correctly, select serial connection using CONFIG >SERIAL in the RM menu, set the baud rate, and assign camera addresses. Note

If a connected camera is changed after completing the configuration, the cameras must be configured again.

7

Turn the SELECT knob to move the cursor to CONFIRM.

8

Turn the VALUE knob to change NO to YES, then press the VALUE button. The unit reboots automatically.

2~8 1

Upon rebooting, the serial connection setting is completed.

1

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

2

Turn the SELECT knob to move the cursor to CONFIG.

3

Press the SELECT button. The CONFIG menu appears.

4

Turn the SELECT knob to move the cursor to SERIAL, and press the SELECT button. The SERIAL menu appears. Set the baud rate, as required. Turn the SELECT knob to move the cursor to BAUD RATE, turn the VALUE knob, and select 9600 or 38400. The default setting is 9600.

5

Turn the SELECT knob to move the cursor to APPLY.

6

Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. The following message appears after changing the connection method from LAN connection to serial

23

Connection with a video switcher By connecting the tally output of a video switcher to the GPI I/O connector of the unit, the tally lamps of the unit light up in unison with the switcher operation which you can use to switch the target camera to control. The following diagram shows the connection with an MCX-500 Multi-Camera Live Producer as an example. Connection example

IR SELECT

CAMERA SETUP

1 2 3

1 2 3 4 5 6 7 8 9

R

IR SELECT

ON

1 2 3

1 2 3 4 5 6 7 8

SYSTEM SELECT

IN VISCA RS - 422 OUT

LAN

12V

VISCA RS-422

OFF

ON

HD

SD

RGB/COMPONENT

75

OSD ON OFF

MIC

RAUD RATE R

HDMI OUT

MONITOR OUT SDI 1 SDI 2

LINE OUT SDI 1 SDI 2

EXT SYNC IN

VISCA RS-422

IR SELECT

L

IN VISCA RS-232 OUT EXT SYNC IN

(PLUG IN POWER)

S VIDEO

1

BRBK-IP10

TERMINATION

VIDEO

2

DC IN 12V

SDI OUT DATA MIX OFF ON

ON OFF

LAN SYSTEM SELECT

HDMI OUT

BRC-X1000, BRC-H800 Video signal

SDI OUT

SDI OUT

HD

SD

LAN

SRG-360SHE

BRC-H900

Video signal Video signal

MCX-500 Multi-Camera Live Producer

RM-IP500 To video monitor

Tally signal

Tally/contact signal: Connection cable with D-sub 15-pin connectors Video signal: HDMI cable Video signal: Connection cable with BNC connectors

24

The buttons and LED indicators start blinking, and a one-time password for accessing the unit from a web browser is displayed on the LCD panel.

Using a Setup PC When the unit is connected with cameras by LAN connection, you can save the settings saved on the unit to a setup PC by connecting the PC to the network. The configuration data saved on the PC can be used to recover settings if a failure occurs or can be used to configure another remote controller.

Saved configuration data • Settings saved on the unit • Camera table • Control panel status

Notes

• The one-time password will become invalid if the unit is rebooted or UPDATE MODE is set to OFF. In this case, acquire another one-time password. • To return to normal operating mode after setting UPDATE MODE to ON, set UPDATE MODE to OFF and then press the CANCEL button.

For details about connecting the setup PC to a network, see “Connecting remote controllers, cameras, and setup PC using LAN connection” (page 16). System requirements for the setup PC The following operating environment is required for the PC on which to install the setup software (as of March, 2017). • CPU: Intel Core2 Duo 2.4 GHz or higher (recommended) • Memory: 1 GB or more (recommended) • Hard disk: More than 50 MB free space • OS: Microsoft Windows 7, Windows 8.1 Pro, Windows 10 Pro 32-bit or 64-bit version • Web browser: Windows Internet Explorer Ver. 11.0

7

The Windows authentication dialog appears.

8

Enter the user name and password in the Windows authentication dialog. • User name: RM_IP_USER • Password: (One-time password obtained by the UPDATE MODE setting.)

9

Click the OK button. The [Backup/Restore] screen appears.

Accessing a remote controller To access the unit from the setup PC, perform the following procedure beforehand using the RM menu.

1 2

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

Press the SELECT button. The MAINTENANCE menu appears.

4

Turn the SELECT knob to move the cursor to UPDATE MODE.

5

Press the SELECT button. The UPDATE MODE setup screen appears.

6

Saving configuration data on a PC (Backup)

Turn the SELECT knob to move the cursor to MAINTENANCE.

3

Access the URL of the target IP controller using a web browser on the PC. http://:52382/backup/

1

Access the URL of the remote controller whose configuration data you want to save using a web browser on the PC. http://:52382/backup/

2

Access the save target remote controller. For details about the access method, see “Accessing a remote controller” (page 25). The [Backup/Restore] screen appears.

3

Turn the VALUE knob to change OFF to ON, then press the VALUE button.

25

Click the [Backup] button. The configuration data backup starts. The default file name of the configuration data file is rm-ip500.cfg.

Loading a saved configuration file into the unit or another remote controller (Restore)

1

Access the URL of the remote controller to which you want to load configuration data using a web browser on the PC. http://:52382/backup/

2

Access the load target remote controller. For details about the access method, see “Accessing a remote controller” (page 25).

Note

To use the RM-IP Setup Tool, set MAINTENANCE >UPDATE MODE to ON in the RM menu.

The [Backup/Restore] screen appears.

3

Click the [Browse] button. The file selection dialog appears.

4

Specify the configuration data to load.

5

Click the [Restore] button on the [Backup/Restore] screen. The configuration data restore starts. When the configuration data is restored, the following message appears and then the remote controller reboots.

About the RM-IP Setup Tool This is a software tool for configuring remote controller settings. It is used to configure the following. • IP address settings • Camera assignments • Swapping camera numbers • Checking camera tables Install the software on the setup PC for the unit. The setup tool software and setup tool guide can be downloaded from the download site. For details, refer to the “RM-IP Setup Tool Guide.”

26

up. When the camera is off (standby), the button is not lit. • You can turn all cameras registered in the camera table on/off (standby) at the same time by setting CONFIG >CAM POWER to ALL in the RM menu and pressing the CAM POWER button.

Operations Before operation, make sure that cameras, the unit, and peripheral devices are installed and connected correctly.

Turning on the Power 1

Turn on the camera(s).

2

Set the power switch on the rear of the unit to the ^ (on) position.

Selecting a Camera Assign camera numbers to the cameras, and then select a camera number on the camera selection block when you want to control the corresponding camera.

Note

When the unit is mounted in a console desk, turn the power on/off using the main power supply of the console desk.

1

When the unit is first turned on, all the buttons on the control panel light up and then turn off. Next, the buttons that were selected when the unit was last turned off light up. The CAMERA 1 button is lit yellow the first time the unit is turned on. When using a LAN connection, the camera group number that was selected when the unit was last turned off is displayed in the group number display.

3

2

The number of camera numbers that can be assigned to cameras to control varies depending on the use of LAN connection or serial connection. The method of selecting the camera number also is different.

Turn on the peripheral devices. Notes

Selecting a camera when using LAN connection

• Be sure to turn on the power of the cameras before the power of this unit. Otherwise, the unit cannot recognize the connected cameras. • Do not touch the joystick or ZOOM lever when turning on the power of the unit. Touching the joystick or ZOOM lever may affect the calibration of the origin point.

For LAN connection, ten camera numbers are assignable in camera groups 1 to 10, supporting assignment of up to 100 cameras.

1

Select the camera group to which the target camera belongs using the GROUP LEFT button and GROUP RIGHT button. You can select from group 1 to 10. The number of the selected group is displayed in the group number display. After switching the group number, the CAMERA 1 button is selected in the group.

2

Press the number of the CAMERA button to select. The selected button lights in yellow. For example, select group 2 and press the CAMERA 5 button to select the 15th camera.

To turn the unit off To turn the unit off to change connection or perform maintenance, use the reverse procedure of turning the unit on.

To turn the cameras on/off (standby) using the unit If power is supplied to a camera, you can turn the camera on/off (standby) using the CAM POWER button of the color adjustment block. • Select the camera that you want to turn on/off (standby), and press the CAM POWER button. When the camera turns on, the CAM POWER button lights

27

Selecting a camera when using serial connection

Tally input change Target camera No tally input

You can select a camera number using the CAMERA 1 to CAMERA 7 buttons. The pressed CAMERA button lights in yellow, and the camera assigned with the same camera number as the button becomes the target camera. For serial connection, up to camera number 7 can be assigned. In a serial connection, groups are not used, hence the group buttons do not light up.

Change from no tally The camera corresponding to the tally input to tally input input number automatically becomes received the target camera. If multiple numbers are input, the camera with the lowest number becomes the target camera. Tally input continues

The camera number button for the selected camera is lit yellow. When a camera is turned on or is in standby mode, the camera number buttons for cameras that can be operated are lit blue.

• When set to ON AIR, on-air tally mode is selected. The tally output of the camera selected by the external device is displayed by the corresponding tally input lamp of the unit. Note that the target camera cannot be switched in conjunction with the tally input, but must be switched using the camera buttons on the unit. The tally lamp on the corresponding camera can also be set to light up in response to the tally input. For details, see “CAMERA LINK” (page 47).

About the tally lamp indicators When the GPI I/O connector of the unit is configured as an input, you can connect the tally output of an external device to the unit to display tally lamps (ON AIR TALLY mode), or switch the target camera in response to the operation of the external device (NORMAL TALLY mode). Set CONFIG >GPI I/O >SETTING to INPUT in the RM menu.

2

Set CONFIG >GPI I/O >TALLY MODE in the RM menu. • When set to NORMAL, normal tally mode is selected. The target camera of the unit is switched in response to the tally output of the external device, and the corresponding tally input lamp lights up.

If there is only one tally input number, the target camera cannot be changed. If there are multiple tally input numbers, you can select one of them to become the target camera.

Change from tally The current target camera does not input to no tally input change.

About the color of camera buttons

1

The CAMERA 1 to CAMERA 10 buttons for all target cameras can be selected.

When the GPI I/O connector is used as a contact output connector, the number of the target camera is sent to the connected external device. When CONFIG >GPI I/O >SETTING is set to OUTPUT in the RM menu, the camera number of the selected camera is output to the external device. You can also display the tally lamp on the camera selected on the unit. For details, see “CAMERA LINK” (page 47).

You can also display the tally lamp on the corresponding camera. For details, see “TALLY MODE” (page 47). Note

If the tally input changes while NORMAL is selected, the target camera will change as follows.

28

To face the camera toward the front (pan/ tilt position reset)

Operating a Camera

Press and hold the button on the joystick.

Pan and tilt control Speed adjustment Pan/tilt position reset

2 3

If you accidentally move the camera head with your hand Press the P/T RST (pan/tilt reset) button to reset the pan/ tilt position.

If the camera moves in a different direction than the joystick

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the joystick control block.

3

Operate the joystick to pan or tilt the camera. While checking the picture on the screen, incline the joystick in the desired direction. The panning/tilting speed changes according to the angle at which you incline the joystick. Return the joystick to the center position to stop pan/tilt operation.

By default, the camera pans to the right whenever the joystick is inclined to the right. If you want the camera to face toward the opposite direction, for example, when changing the direction of the camera while checking the picture on a screen, you can change the orientation using CONFIG >DIRECTION in the RM menu. For details about configuration, see “DIRECTION” (page 46). Joystick

Incline to the right

To adjust the pan/tilt speed Incline to the right

You can adjust the pan/tilt speed, obtained when you incline the joystick at the maximum angle, and the change in speed in response to the angle of inclination. Turning the PAN-TILT SPEED knob clockwise increases the speed, and turning counterclockwise decreases the speed.

Movement of the camera

CONFIG >DIRECTION setting Pan operation: Set JOYSTICK PAN to STANDARD. Tilt operation: Set JOYSTICK TILT to STANDARD. Pan operation: Set JOYSTICK PAN to REVERSE. Tilt operation: Set JOYSTICK TILT to REVERSE.

Note

The setting above only changes the control signal from the unit, and does not change the setting of the camera itself.

If the STANDBY lamp of the camera blinks When the camera is moved or turned by hand or by external force, the camera system may not be able to memorize the pan/tilt position properly.

29

Release the joystick to stop zooming.

In this case, press the P/T RST (pan/tilt reset) button to reset the pan/tilt position.

Subject appears smaller. (Wide angle)

Subject appears larger. (Telephoto)

Note

When you perform pan/tilt operation while the camera is in telephoto mode, the speed of movement of the image may appear erratic.

STANDBY blinks.

Zoom control To control the zoom using the ZOOM lever on the lens control block

The camera zoom can be operated using either the ZOOM ring on the top of the joystick or the ZOOM lever in the lens control block. You can set which is used to control the zoom using CONFIG >RM SETUP >ZOOM in the RM menu. For details about configuration, see “RM SETUP” (page 46).

2

You can adjust the zoom speed using the ZOOM SPEED knob on the lens control block.

3

To control the zoom using the ZOOM ring on the top of the joystick

2

3

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the joystick control block.

3

Turn the ZOOM ring on the top of the joystick counterclockwise/clockwise.

30

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the lens control block.

3

Move the ZOOM lever left/right. Moving the lever to the left makes the subject appear smaller (Wide angle). Moving the lever to the right makes the subject appear larger (Telephoto). The zoom speed changes depending on the pressure applied to the lever and the setting of the ZOOM SPEED knob. Turning the ZOOM SPEED knob clockwise increases the zoom speed, and turning counterclockwise decreases the zoom speed. You can change the orientation of the zoom lever using CONFIG >DIRECTION in the RM menu (page 46).

Adjusting the brightness

Adjusting a Camera The functions that can be operated vary depending on the camera model and configuration. For details, see “Function of Buttons/Knobs in Each Block by Camera Model” (page 41).

Auto adjust

2

Adjusting the focus Manual adjust

2 Auto adjust

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the lens control block.

One-push auto adjust

Manual adjust

To adjust the exposure automatically

1 2

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

Press the AE button, turning it on (button is lit).

Press the ACTIVE button, turning it on (button is lit), on the lens control block. The lens control block becomes enabled.

1

Set CONFIG >RM SETUP >AE CONFIG to MANUAL or IRIS Pri in the RM menu. For details about AE CONFIG, see “AE CONFIG” (page 46).

2

Press the AE button, turning it off (button is not lit).

3

Turn the IRIS knob to adjust the iris of the camera.

To adjust the exposure manually

To adjust the focus automatically Press the AUTO FOCUS mode button, turning it on (button is lit yellow). Auto focus mode is activated. In auto focus mode, the camera focuses on the subject in the center of the screen automatically.

Operation using IRIS, GAIN, and SHUTTER buttons

To adjust the focus manually Press the AUTO FOCUS mode button, turning it off (button is not lit). Turn the FOCUS knob counterclockwise/clockwise to adjust the focus while monitoring the image of the subject. The focus speed is set using the FOCUS SPEED knob. Turning the knob clockwise increases the focus speed, and turning counterclockwise decreases the focus speed.

One-push auto focus during manual focus adjustment Press the O.P.A.F (one-push auto focus) button. The button blinks yellow for a few seconds, and then the camera focuses on the subject in the center of the screen automatically.

31

1

Set CONFIG >RM SETUP >AE CONFIG to MANUAL, IRIS Pri, GAIN Pri, or SHUTTER Pri in the RM menu. For details about AE CONFIG, see “AE CONFIG” (page 46).

2

Press the AE button, turning it off (button is not lit).

3

Press the IRIS, GAIN, or SHUTTER button on the menu control block. The setting is displayed on the LCD panel and can be adjusted using the VALUE knob (FUNCTION menu). For details about the FUNCTION menu, see “Setting Specific Functions using Shortcuts (FUNCTION Menu)” (page 37).

Backlight compensation Use the following procedure to compensate for backlighting if the subject appears dark due to a light source behind the subject.

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the color adjustment block.

3

Press the ASSIGN 2 button.

To cancel flicker compensation Press the ASSIGN 2 button, turning it off (button is not lit).

2 3

Adjusting the white balance Position a white object under the same lighting conditions as the subject you want to shoot, and zoom in on it on the screen. (You can use a white wall or other object.) The white balance is adjusted against the white object.

Backlight compensation functions when AE mode is enabled (AE button is lit).

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the color adjustment block.

3

Press the ASSIGN 1 button.

Auto adjust

2 Manual adjust

To cancel backlight compensation Press the ASSIGN 1 button, turning it off (button is not lit). Note

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the color adjustment block.

On the BRC-H900, to turn the AE button off, also turn ASSIGN 1 (backlight compensation) off.

Flicker compensation Use the following procedure if there is any flicker in the image of the subject due to the effects of fluorescent lighting or other light sources.

To adjust the white balance automatically

1

Set OPERATION >WHITE >WB MODE in the RM menu. For details about settings, see “WB MODE” (page 44). • Setting to AUTO1 or AUTO2 automatically adjusts the white balance according to the corresponding setting. • Setting to ONE PUSH enables the O.P.AWB (one-push auto white balance) button.

2

If ONE PUSH is selected in step 1, press the O.P.AWB (one-push auto white balance) button. The button blinks red for a few seconds, and then the camera white balance is adjusted automatically.

2 3

32

To adjust the white balance manually

1 2

The button blinks red for a few seconds, and then the camera black balance is adjusted automatically.

Set OPERATION >WHITE >WB MODE to MANUAL in the RM menu. For details about settings, see “WHITE” (page 43).

To adjust the black balance manually Adjust the black balance using the R-BLACK knob and B-BLACK knob. Adjust the R-BLACK value using the R-BLACK knob, and the B-BLACK value using the B-BLACK knob. Turning the knob counterclockwise decreases the RBLACK/B-BLACK value, and turning clockwise increases the R-BLACK/B-BLACK value.

Adjust the white balance using the R-WHITE knob and B-WHITE knob. Adjust the red gain using the R-WHITE knob, and the blue gain using the B-WHITE knob. Turning the knob counterclockwise decreases the red/blue hue, and turning clockwise increases the red/blue hue.

To adjust the master black

Adjusting the black balance

1

Adjust the black balance when you use a camera for the first time or after a long time of non-use, or if the ambient temperature of the camera has changed significantly.

Set the M.BLACK value using OPERATION >BLACK in the RM menu.

2

Adjust the master black using the MASTER BLACK knob. Turning the knob counterclockwise decreases the master black level, and turning clockwise increases the master black level.

Note

Check that OPERATION >BLACK >ABB MODE is set to ON in the RM menu. The black balance function cannot be executed if ABB MODE is set to OFF.

Auto adjust

2

Manual adjust Master black adjust

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press the ACTIVE button, turning it on (button is lit), on the color adjustment block.

3

Adjust the black balance automatically or manually.

To adjust the black balance automatically

1

Set OPERATION >BLACK >ABB MODE to ON in the RM menu.

2

Press the O.P.ABB (one-push auto black balance) button.

33

The preset number is displayed at the bottom right on the LCD panel of the menu control block.

Storing the Camera Status (Preset Function)

7

The camera status, comprising the camera position, zooming, focusing, backlighting compensation, flicker compensation, and white/black balance adjustments, can be stored in the memory of the camera. You can set the speed of movement between positions for preset memory operation using OPERATION >PRESET in the RM menu. This setting is applied to all presets. The speed of movement default setting is 24. The number of presets varies depending on the camera. For details, refer to the specifications for the camera.

Press and hold the STORE button. The camera status is stored in the memory of the camera. The preset number at the bottom right of the LCD panel disappears, and storing is completed when the STORE button becomes lit. After registering a preset, we recommend that you check that the camera status is stored correctly by recalling the preset.

Recalling stored status There are two methods for recalling stored status: direct recall and number recall.

Direct recall

1

3

1

Direct recall With the DIRECT RECALL button on (button is lit yellow), press the PRESET 1 to PRESET 10/0 buttons to recall preset numbers 1 to 10. Only preset numbers 1 to 10 can be recalled using direct recall.

Number recall

6 7

Number recall

1

Press the ACTIVE buttons, turning them on (buttons are lit), on the joystick control block and preset memory control block.

2

Select the camera whose status you want to store. For details about selection, see “Selecting a Camera” (page 27).

3

Operate the joystick to pan/tilt the orientation of the camera.

4

Perform zoom, focus, backlight compensation, flicker compensation, and white/black balance adjustments, as required.

5 6

With the DIRECT RECALL button off (button is not lit), enter the preset number using the PRESET 1 to PRESET 10/0 buttons, in the same way as when storing a preset, and then press the RECALL button. In this method, the entered preset number is displayed at the bottom right on the LCD panel of the menu control block. Preset numbers 1 to 100 can be recalled using number recall.

Changing the speed of movement between positions

Check that the DIRECT RECALL button is off. Turn it off if it is currently turned on. Enter the preset number you want to store. Use the PRESET 10/0 button to enter a “0” digit. Preset numbers in the range 1 to 100 can be set.

34

1

Check that the DIRECT RECALL button is off. Turn it off if it is currently turned on.

2

Select a camera, and recall the position you want to change.

3

Set the speed using OPERATION >PRESET >SPEED in the RM menu.

4

Press and hold the STORE button.

Note

Operating the Camera Setup Menu from the Unit (Camera Menu Operation Mode)

Subsequently when a preset is stored, the speed of movement between positions changes to the value set in step 3.

You can operate the setup menu on the camera using the knobs and buttons on the menu control block and the joystick. Notes

• In camera menu operation mode, the menu is displayed on the monitor output of the camera. Nothing is displayed on the LCD panel of the unit. • Operation according to the camera specifications is required to save settings.

Buttons and knobs used for camera menu operations Operation

Buttons and knobs used

Activate camera Press and hold the CAM MENU button. menu mode. Select a setup menu item.

Turn the SELECT knob or tilt up/down using the joystick.

Confirm the setup menu item selection.

Press the SELECT button or the joystick button.

Select a setup menu sub item.

Turn the SELECT knob or pan left/right using the joystick.

Change the Turn the VALUE knob or press the joystick setting of the button. setup menu sub item. Confirm the changed setting. Save settings.

Saved on the camera using the camera preset memory function.*

Go back one level in the menu.

Press and hold the CAM MENU button or press the CANCEL button.

* For details about items saved with a preset number, refer to the operating instructions of each camera.

35

Press the joystick button to confirm the selection of items and settings.

3

4

2

1

Select the target camera to control. For details about selection, see “Selecting a Camera” (page 27).

2

Press and hold the CAM MENU button, turning it on (button is lit yellow). Camera menu operation mode is activated. The camera setup menu is displayed on the output video monitor for the camera on-screen display.

3

Operate the camera setup menu using the SELECT knob/button, VALUE knob, CANCEL button, and joystick. SELECT knob Selects menu items. The cursor moves up/down as the SELECT knob is turned counterclockwise/clockwise. SELECT button Press this button to confirm the selection of menu items. If a menu item has sub items, those sub items are displayed. VALUE knob Selects settings. The setting changes as the VALUE knob is turned counterclockwise/clockwise. CANCEL button Press this button to go back one level in the menu and to exit the setup menu. Note

On the SRG-360SHE, pressing the CANCEL button during menu operation will exit menu mode. To go up one level in the menu, press and hold the CAM MENU button. Operation using the joystick Select a setup menu item using tilt operation, and select the setting using pan operation.

36

Exit camera setup menu mode. Press the CANCEL button repeatedly until the menu disappears.

Operation using IRIS, GAIN, and SHUTTER buttons

Setting Specific Functions using Shortcuts (FUNCTION Menu)

4

When the IRIS, GAIN, SHUTTER, ASSIGN 4, ASSIGN 5, or ASSIGN 6 button is pressed on the menu control block, the setup item and setting of the function assigned to the button is displayed on the LCD panel. You can change the setting using the VALUE knob. This allows you to set some functions more quickly than by using normal menu operations.

3

Notes

• Depending on the camera model, the settings displayed on the unit and camera menu display may not be the same. In this case, the settings displayed in the camera menu are the actual settings. • When changing a setting, there may be some delay before the display is updated.

Buttons and knobs used for FUNCTION menu operations Operation

Buttons and knobs used

Activate FUNCTION menu mode.

Press the IRIS, GAIN, SHUTTER, or ASSIGN 4 to ASSIGN 6 button.

Set CONFIG >RM SETUP >AE CONFIG to MANUAL, IRIS Pri, GAIN Pri, or SHUTTER Pri in the RM menu. For details about AE CONFIG, see “AE CONFIG” (page 46).

2

Press the AE button, turning it off (button is not lit). The IRIS, GAIN, or SHUTTER button operation which is enabled (lit blue) is determined by the AE CONFIG setting.

3

Press the IRIS, GAIN, or SHUTTER button. The button is lit yellow, and the adjustment item and setting are displayed on the LCD panel.

4

Set the value using the VALUE knob.

Note

Change the Turn the VALUE knob. Confirmation of setting of the changed settings is not required. setup menu sub item. Save settings.

1

If an adjustment is not supported, “---” is displayed for the adjustment value.

Saved on the camera using the camera preset memory function.*

IRIS button Sets the iris value of the camera.

* For details about items saved with a preset number, refer to the operating instructions of each camera.

GAIN button Sets the gain value of the camera.

SHUTTER button Sets the shutter speed of the target camera. The settings display varies depending on the frame rate setting (59.94 Hz or 50 Hz). For details about the frame rate setting, see “CAMERA FREQ” (page 46).

37

Operation using ASSIGN 4, ASSIGN 5, and ASSIGN 6

Checking Camera Settings Status (Status Display)

Press ASSIGN 4, ASSIGN 5, or ASSIGN 6. The button is lit yellow, and the adjustment item and setting of the function assigned to the button is displayed on the LCD panel. In this version, the following functions have been assigned, and cannot be changed.

Press the ASSIGN 3 button on the color adjustment block to display the current iris, gain, shutter speed, and zoom position status of the target camera on the LCD panel for about three seconds.

ASSIGN 4 button Sets DETAIL LEVEL on the target camera.

ASSIGN 5 button Sets KNEE POINT on the target camera.

ASSIGN 6 button Sets AE LEVEL on the target camera.

Press ASSIGN 3 to display the camera settings status on the LCD panel.

After approximately three seconds, the display automatically turns off. ZOOM position indicator xxssssssa

TWIDE TELEt s represents the divisions between the WIDE and TELE positions, while x represents the current position from the WIDE end. a indicates Clear Image Zoom and the digital zoom range. The indicator changes to z when shooting in that range.

38

Default values

Restoring Factory Default Settings

The state of each control block on the control panel is given below. • The ACTIVE button is on (button is lit) on the color adjustment block, lens control block, and preset memory control block. • The DIRECT RECALL button is on (button is lit) on the preset memory control block. • The CAMERA 1 button is on (button is lit yellow) on the camera selection block, and the CAMERA buttons that were blue are off (not lit). "1" (group number 1) is displayed in the group number display. • The RM menu button is on (button is lit) in the menu control block, and the top menu is displayed on the LCD panel.

You can restore all settings stored in the unit to their factory default values. This operation is performed using MAINTENANCE >RESET in the RM menu.

1

Press the RM MENU button, turning it on (button is lit yellow). The RM menu top menu appears.

2

Turn the SELECT knob to move the cursor to MAINTENANCE.

3

Press the SELECT button. The MAINTENANCE menu appears.

4

Turn the SELECT knob to select RESET. The RESET screen appears.

5 6

All camera information in the camera table is cleared, and the settings for camera information items are undefined. The settings of all setup items in the RM menu are returned to their default values, shown in the following table.

Turn the SELECT knob to move the cursor to RESET ALL. pRESET ALL : : NOT EXEC

Menu item

Sub menu item

OPERATION PRESET

Turn the VALUE knob to change NOT EXEC to EXEC, then press the VALUE button. The following message appears, prompting you to reboot the unit.

CONFIG

Setup item

Default value

SPEED

24

RM SETUP AE CONFIG

MANUAL

CAM POWER EACH ZOOM

LEVER

CAMERA FREQ

59.94*

DIRECTION JOYSTICK PAN

STANDARD

JOYSTICK TILT

STANDARD

ZOOM LEVER

STANDARD

FOCUS DIAL STANDARD

7 8

GPI I/O

SETTING

INPUT

Turn the SELECT knob to move the cursor to CONFIRM. pCONFIRM : NO

TALLY MODE

NORMAL

COMMAND SEL

STANDARD

Turn the VALUE knob to change NO to YES, then press the VALUE button.

CAMERA LINK

ON

LAN

The unit reboots automatically.

SERIAL CONTROL I/F

39

IP

192.168.0.10

SM

255.255.255.0

GW

0.0.0.0

APPLY

NOT EXEC

BAUD RATE

9600

APPLY

NOT EXEC LAN

Menu item

Sub menu item

Setup item

Default value

AUTO IP SETUP

SETUP IP

[FROM] IP

192.168.0.1

[TO] IP

192.168.0.254

SETUP IP

NOT EXEC

ASSIGN CAM

[FROM] 01 GROUP NUM [FROM] CAMERA NUM

CLEAR TABLE

01

KEEP IP

NOT EXEC

CLEAR TABLE

NOT EXEC

SWAP CAM CAMERA A IP (IP address)

01-01 ---.---.---.---

MAC (MAC XX-XX-XX-XX-XX-XX address) CAMERA B IP (IP address)

01-01 ---.---.---.---

MAC (MAC XX-XX-XX-XX-XX-XX address) SWAP A<=>B NOT EXEC CAMERA TABLE

GROUP NUM 01-LOWER CAM INFO IP ADD(0105) (IP address)

IP ADD ---.---.---.---

MAC XX-XX-XX-XX-XX-XX ADD(01-05) (MAC address) * Default value of 50 for models sold in China.

40

Function of Buttons/Knobs in Each Block by Camera Model Yes: Supported –: Not supported Control block

Lens control block

Color adjustment block

Button/knob

Function

Conditions

BRCX1000/ H800

BRCH900

SRG360SHE

AE button

Exposure mode selection

• When the button is on (lit): Full auto. • When the button is off (not lit): Follows CONFIG >RM SETUP >AE CONFIG setting in the RM menu.

Yes

Yes

Yes

FOCUS adjustment knob

Manual focus adjustment

Enabled when the AUTO FOCUS mode button is not lit.

Yes

Yes

Yes

O.P.A.F (one-push auto focus) button

One-push auto focus Enabled when the AUTO FOCUS adjustment mode button is not lit.

Yes

Yes

Yes

IRIS knob

Iris setting adjustment

Enabled when the AE button is not lit, and CONFIG >RM SETUP >AE CONFIG is set to MANUAL or IRIS Pri in the RM menu.

Yes

Yes

Yes

O.P.AWB (one-push auto white balance) button

One-push white balance auto adjustment

Enabled when OPERATION >WHITE >WB MODE is set to ONE PUSH in the RM menu.

Yes

Yes

Yes

O.P.ABB (one-push auto black balance) button

One-push black balance auto adjustment

Enabled when OPERATION >BLACK >ABB MODE is set to ON in the RM menu.



Yes



BARS button

Toggle color bars output on/off.





Yes



ASSIGN 1 button

Toggle backlight Enabled when the AE button is lit. compensation on/off.

Yes

Yes*1

Yes

ASSIGN 2 button

Toggle flicker Enabled when FLICKER CANCEL compensation on/off. >MODE is set to ON in the camera menu.

Yes

Yes



ASSIGN 3 button

Display the status of the iris, gain, shutter speed, and zoom position.



Yes

Yes

Yes

R-WHITE knob/ B-WHITE knob

R gain and B gain adjustment

Enabled when OPERATION >WHITE >WB MODE is set to MANUAL in the RM menu.

Yes

Yes

Yes

R-BLACK knob/ B-BLACK knob

R black and B black adjustment

Enabled when OPERATION >BLACK >ABB MODE is set to OFF in the RM menu.



Yes



MASTER BLACK knob

Master black adjustment



Yes

–*2



41

Yes: Supported –: Not supported Control block

FUNCTION menu of menu control block

Button/knob

ASSIGN 4 button

ASSIGN 5 button

ASSIGN 6 button

Function

Conditions

DETAIL LEVEL display



Adjustment using VALUE knob after DETAIL LEVEL is displayed

On the BRC-H900, enabled if DETAIL is set to ON in the camera menu.

KNEE POINT display



Adjustment using VALUE knob after KNEE POINT is displayed

Enabled when KNEE is set to ON in the camera menu, and KNEE MODE is set to MANUAL.

AE level display

Enabled when the AE button is lit, or if the AE button is not lit and CONFIG >RM SETUP >AE CONFIG is not set to MANUAL in the RM menu.

BRCX1000/ H800

BRCH900

SRG360SHE

Yes

Yes

Yes*3

Yes

Yes



Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes*4

Yes*4

Yes*5

Yes*5

Yes*5

Adjustment using Enabled when OPERATION VALUE knob after >EXPOSURE >EX-COMP is set to AE level is displayed ON in the RM menu. IRIS button (lit blue when enabled)

IRIS setting display

Enabled when the AE button is not lit.

Adjustment using VALUE knob after IRIS setting is displayed

Enabled when the AE button is not lit, and CONFIG >RM SETUP >AE CONFIG is set to MANUAL or IRIS Pri in the camera menu.

GAIN button (lit blue when enabled)

GAIN setting display Enabled when the AE button is not lit.

SHUTTER button (lit blue when enabled)

Shutter speed display Enabled when the AE button is not lit.

Adjustment using VALUE knob after GAIN setting is displayed

Adjustment using VALUE knob after shutter speed is displayed

Enabled when the AE button is not lit, and CONFIG >RM SETUP >AE CONFIG is set to MANUAL or GAIN Pri in the camera menu.

Enabled when the AE button is not lit, and CONFIG >RM SETUP >AE CONFIG is set to MANUAL or SHUTTER Pri in the camera menu.

*1 Enabled when Exposure Mode is set to FULL AUTO or BACK LIGHT in the camera menu. *2 Setting is enabled in the camera menu. *3 The APERTURE setting of the PICTURE menu on the camera is applied. *4 GAIN Pri cannot be selected. *5 Setting changes with the frame rate (50 Hz/59.94 Hz). Set CONFIG >RM SETUP >CAMERA FREQ in the RM menu to the frame rate setting of the camera.

42

RM Menu List

OPERATION

Menu item

Sub menu item

Setup item

See

OPERATION page 43

EXPOSURE

EX-COMP AE LEVEL WB MODE R. WHITE B. WHITE OFFSET ABB MODE R. BLACK B. BLACK M. BLACK SETTING LEVEL SETTING KNEE MODE POINT SLOPE MATRIX SELECT SPEED AE CONFIG CAM POWER ZOOM CAMERA FREQ

page 43

WHITE

BLACK

DETAIL KNEE

MATRIX

CONFIG page 46

PRESET RM SETUP

SW ASSIGN DIRECTION

GPI I/O

AUTO IP SETUP page 48

MAINTENANCE page 49

LAN SERIAL CONTROL I/F SETUP IP ASSIGN CAM CLEAR TABLE SWAP CAM CAMERA TABLE MODEL INFO

UPDATE MODE RESET

You can check and change camera menu settings while operating a camera. This menu is also used to set and change the speed of movement betweens positions when using the preset memory function. During operation, the settings of the OPERATION menu setup items display the settings configured on the camera. Accordingly, default settings are not indicated in the description of each setting. To store the settings changed using this menu, use the preset memory function of the camera. For details about items saved with a preset number, refer to the operating instructions of each camera.

page 43 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 44 page 46 page 46 page 46 page 46 page 46 JOYSTICK PAN page 46 JOYSTICK TILT page 47 ZOOM LEVER page 47 FOCUS DIAL page 47 SETTING page 47 TALLY MODE page 47 COMMAND SEL page 47 CAMERA LINK page 47 page 48 page 48 page 48 page 48 page 48 page 48 page 48 page 48 MODEL page 49 S/NO page 49 VERSION page 49 page 49 page 49

Notes

• Depending on the camera model, the settings displayed on the unit and camera menu display may not be the same. In this case, the settings displayed in the camera menu are the actual settings. • When changing a setting, there may be some delay before the display is updated.

EXPOSURE Sets the exposure compensation function of the target camera.

EX-COMP Turns the exposure compensation mode on/off.

AE LEVEL Sets the control level for automatic camera brightness control (exposure compensation level).

WHITE Sets the white balance adjustment function of the target camera.

43

WB MODE Settings

Description

AUTO1

Automatically adjusts the white balance using AUTO1.

AUTO2

Automatically adjusts the white balance using AUTO2.

INDOOR

LEVEL Adjusts the level of detail correction.

KNEE Sets the KNEE correction function on the target camera.

Adjusts to a white balance suitable for indoor shooting.

SETTING

OUTDOOR Adjusts to a white balance suitable for outdoor shooting.

Turns the KNEE correction function on/off. When set to ON, the high luminance parts of the image are compressed.

ONE PUSH Executes a white balance adjustment. Shoot a large white object in the center of the screen and press the O.P.AWB button. MANUAL

KNEE MODE

Adjusts the white balance manually. Selecting this enables the R. WHITE and B. WHITE items.

R. WHITE

Settings

Description

AUTO

Automatically calculates the optimum luminance level at which knee correction is applied from the luminance level of the image being shot.

MANUAL

Allows you to adjust the luminance level at which knee correction (POINT and SLOPE) is applied, irrespective of the luminance level of the image being shot.

Sets the R. WHITE value.

B. WHITE Sets the B. WHITE value.

OFFSET

POINT

Adjusts the offset level of the white convergence point. Negative values shift the convergence point in the blue direction, and positive values shift the convergence point in the red direction.

Adjusts KNEE POINT.

SLOPE Adjusts the gradient of the slope above the knee point (degree of compression).

BLACK MATRIX

Sets the black balance adjustment function of the target camera.

Sets the MATRIX adjustment function on the target camera.

ABB MODE Turns the black balance adjustment function on/off.

MATRIX Turns the MATRIX adjustment function on/off. When set to ON, you can enhance or weaken a specific color region while keeping the white convergence point unchanged.

R. BLACK Sets the R. BLACK value.

B. BLACK Sets the B. BLACK value.

SELECT

M. BLACK Sets the M. BLACK value.

Selects a built-in preset matrix used for matrix calculation. You can choose from STD, HIGH SAT, and FL LIGHT.

DETAIL

PRESET

Sets the detail enhancement function of the target camera.

Sets the speed of movement when switching positions using preset memory.

SETTING

SPEED

Turns the detail correction function on/off. When set to ON, you can set the level of detail correction.

Sets the speed of movement when switching positions using preset memory.

44

OPERATION menu support by camera model Yes: Supported –: Not supported Setup item

EXPOSURE

WHITE

BLACK

DETAIL

KNEE

MATRIX

PRESET

Function

Conditions

BRCX1000/ H800

BRCH900

SRG360SHE

EX-COMP

Exposure compensation function on/off



Yes

Yes*1

Yes

AE LEVEL

Exposure compensation level setting

Enabled when EX-COMP is set to ON.

Yes

Yes

Yes

WB MODE

White balance adjustment method selection



Yes

Yes*2

Yes*3

R. WHITE

R. WHITE value setting

Enabled when WB MODE is set to MANUAL.

Yes

Yes

Yes

B. WHITE

B. WHITE value setting

Enabled when WB MODE is set to MANUAL.

Yes

Yes

Yes

OFFSET

Convergence point offset adjustment

Enabled when WB MODE is set to AUTO1, AUTO2, or ONE PUSH.

Yes

Yes



ABB MODE

Black balance adjustment function setting





Yes



R. BLACK

R. BLACK value setting





Yes



B. BLACK

B. BLACK value setting





Yes



M. BLACK

M. BLACK value setting



Yes





SETTING

Detail correction function on/off



Yes*1

Yes

Yes*1

LEVEL

Detail correction level setting

Enabled when SETTING is set to ON.

Yes

Yes

Yes*4

SETTING

KNEE correction function on/off



Yes

Yes



KNEE MODE

KNEE adjustment function Enabled when SETTING is set to AUTO/MANUAL ON. selection

Yes

Yes



POINT

KNEE POINT setting

Enabled when KNEE MODE is set to MANUAL.

Yes

Yes



SLOPE

KNEE slope setting

Enabled when KNEE MODE is set to MANUAL.

Yes

Yes



MATRIX

MATRIX adjustment function on/off



Yes

Yes



SELECT

Built-in preset matrix selection used for matrix calculation

Enabled when MATRIX is set to ON.

Yes

Yes



SPEED

Speed of movement setting – when switching positions using the preset memory function.

Yes

Yes



*1 Always set to ON. Cannot be set to OFF. *2 AUTO2 cannot be selected. *3 When AUTO2 is selected, the ATW white balance mode on the camera is applied. *4 The APERTURE setting of the PICTURE menu on the camera is applied.

45

ZOOM

CONFIG This menu is used to configure functions of the unit.

Settings (Bold: default value)

Description

LEVER

Controls the zoom of the target camera using the ZOOM lever on the lens control block.

JOYSTICK

Controls the zoom of the target camera using the ZOOM ring on the joystick.

CAMERA FREQ Settings (Bold: default value)

Description

59.94

Selects the frame rate for the shutter speed displayed in the menu. You can select from 59.94 [Hz] and 50 [Hz].*

50

Note

During CONFIG menu operation, operation using controls other than the buttons and knobs on the menu control block is not supported.

* The shutter speed is displayed in the status display (page 38) for the ASSIGN 3 button.

SW ASSIGN

RM SETUP

Assign functions to the ASSIGN 1 to ASSIGN 6 buttons of the unit.

Sets the operation of the unit.

AE CONFIG

Note

You can select the following exposure modes when the AE button on the lens control block is off. To apply the setting, after selection, turn the AE button on and then off again. Settings (Bold: default value)

Description

MANUAL

The gain (GAIN), electronic shutter speed (SPEED), and iris (IRIS) can be adjusted manually.

SHUT Pri

Automatically adjusts the exposure using the gain and iris. Adjust the electronic shutter speed (SPEED) manually.

IRIS Pri

Automatically adjusts the exposure using the gain and electronic shutter speed. Adjust the iris (IRIS) manually.

GAIN Pri

Automatically adjusts the exposure using the electronic shutter speed (SPEED) and iris (IRIS). Adjust the gain (GAIN) manually.

In this version, the assignment of the ASSIGN buttons is fixed and cannot be changed. Assign button

Settings

Description

ASSIGN 1

BACK LIGHT

Settings are fixed.

ASSIGN 2

FLICKER

ASSIGN 3

STATUS

ASSIGN 4

DETAIL

ASSIGN 5

KNEE

ASSIGN 6

AE LEVEL

DIRECTION Sets the control direction of the joystick, ZOOM lever, and FOCUS knob.

JOYSTICK PAN

CAM POWER

Settings (Bold: default value)

Description

Settings (Bold: default value)

Description

STANDARD

EACH

Only the target camera turns on/off when using the CAM POWER button.

Inclining the joystick to the right pans the camera to the right. Inclining to the left pans the camera to the left.

REVERSE

ALL

All cameras registered in the camera table turn on/off when using the CAM POWER button.

Inclining the joystick to the right pans the camera to the left. Inclining to the left pans the camera to the right.

46

JOYSTICK TILT Settings (Bold: default value)

Description

STANDARD

Inclining the joystick forward tilts the camera up. Inclining rearward tilts the camera down.

REVERSE

Inclining the joystick forward tilts the camera down. Inclining rearward tilts the camera up.

ZOOM LEVER

Settings (Bold: default value)

Description

NORMAL

Displays the tally input lamp corresponding to the number of the camera with tally input ON, and automatically selects the camera as the target camera.

ON AIR

Displays the tally input lamp corresponding to the number of the camera with tally input ON.

COMMAND SEL

Settings (Bold: default value)

Description

Settings (Bold: default value)

Description

STANDARD

Moving the ZOOM lever to the W side (Wide) zooms out, and moving to the T side (Tele) zooms in.

STANDARD

REVERSE

Moving the ZOOM lever to the W side (Wide) zooms in, and moving to the T side (Tele) zooms out.

Sets the input/output method to STANDARD method. The camera numbers and input/output pin numbers have a 1:1 correspondence. • If the unit and cameras are connected by serial connection, cameras 1 to 7 correspond to input/ outputs 1 to 7. • If the unit and cameras are connected by LAN connection, cameras 1 to 10 in group 1 correspond to input/outputs 1 to 10.

EXPAND

Handles camera numbers as binary numbers. • Tally input numbers 8 and higher in a serial connection are ignored. In this case, the response is equivalent to no input. • Numbers in a LAN connection, corresponding to cameras 1 to 10 in groups 1 to 10, are handled as the numbers 1 to 100. Tally input numbers 101 and higher are ignored. In this case, the response is equivalent to no input.

FOCUS DIAL Settings (Bold: default value)

Description

STANDARD

Turning the FOCUS knob clockwise moves the focus in the Far direction, and turning counterclockwise moves the focus in the Near direction.

REVERSE

Turning the FOCUS knob clockwise moves the focus in the Near direction, and turning counterclockwise moves the focus in the Far direction.

GPI I/O Sets the GPI I/O connector signal format and tally operation mode.

CAMERA LINK SETTING Settings (Bold: default value)

Description

INPUT

Sets the control signal direction of the GPI I/O connector to INPUT. In this case, connect a tally control input signal to the connector.

OUTPUT

Sets the control signal direction of the GPI I/O connector to OUTPUT. In this case, the connector functions as a contact output connector which outputs the camera number of the target camera.

Settings (Bold: default value)

Description

ON, OFF

Turns tally lamp control on/off. The tally lamp control operation varies depending on the combination of the SETTING and CAMERA LINK settings. For details, see “Tally lamp control operation” below.

Tally lamp control operation

TALLY MODE This setting is enabled when SETTING is set to INPUT.

Tally lamp

47

Tally input lamps

CAMERA LINK setting

Control lamps

SETTING setting

OFF

Tally input lamps 1 to 10

Displays the Not lit tally input lamp corresponding to the number of the camera with tally input ON.

Camera tally lamp

The camera tally lamps are not controlled. A tally lamp ON/ OFF command is not sent.

Tally input lamps 1 to 10

Displays the Not lit tally input lamp corresponding to the number of the camera with tally input ON.

ON

Camera tally lamp

IN

Displays the camera tally lamp corresponding to the number of the camera with tally input ON.

AUTO IP SETUP

OUT

This menu is used to configure the automatic assignment of IP addresses of the detected cameras on the network. This is used when the unit and cameras are connected by LAN connection.

SETUP IP Assigns IP addresses to cameras automatically, and then assign the cameras to the camera selection buttons of the unit. For details, see “Assignment using AUTO IP SETUP >SETUP IP” (page 17).

The tally lamp of the target camera becomes the control target, and the camera tally lamp lights up.

ASSIGN CAM Assigns cameras that already have configured IP addresses to the camera selection buttons of the unit. For details, see “Assignment using AUTO IP SETUP >ASSIGN CAM” (page 18).

LAN Configures the network of the unit when the unit and target cameras are connected by LAN connection. For details, see “Setting the IP address of the unit” (page 14).

CLEAR TABLE Clears the camera information. For details, see “To clear the camera table” (page 19).

SERIAL Configures serial connections when the unit and target cameras are connected by serial connection. For details, see “Configuring a serial connection” (page 23).

SWAP CAM Swaps the camera number and camera information of two cameras registered in the camera table. For details, see “To swap camera numbers” (page 19).

CONTROL I/F CAMERA TABLE

Displays the enabled control interface of cameras. When LAN connection is enabled, LAN is displayed. When serial connection is enabled, SERIAL is displayed.

Displays the camera information (IP address and MAC address) registered in the camera table. For details, see “To check the camera table” (page 20).

48

RESET

MAINTENANCE

Resets all settings stored on the unit to their default values. For details, see “Restoring Factory Default Settings” (page 39).

This menu is used to perform maintenance of the unit.

MODEL INFO Displays model information about the unit.

MODEL Display

Description

RM-IP500

Displays the model name of the unit.

S/NO Display

Description

1234567

Displays the serial number of the unit.

VERSION Display

Description

X.XX

Displays the firmware version of the unit.

UPDATE MODE To permit access to the unit from a PC, set UPDATE MODE to ON. Enable update mode when backing up or restoring settings, or using the setup software RM-IP Setup Tool. When UPDATE MODE is set to ON, all operations are disabled, except the VALUE knob and VALUE button operation. To return to normal operation mode, set UPDATE MODE to OFF. For details, see “Using a Setup PC” (page 25). Note

When UPDATE MODE is set to ON, the buttons on the control panel blink at roughly 1-second intervals. Blinking indicates that external access to the unit is permitted. It does not indicate a malfunction.

49

Appendix

Troubleshooting Before bringing in your unit for service, check the following as a guide to troubleshoot the problem. If the problem cannot be corrected, consult with your Sony dealer. Symptom

Cause

The power of the unit is not turned on.

The AC power adapter is not connected to the Insert the power cord firmly as far as it will go. DC IN 12V jack firmly.

The camera cannot be operated with the unit.

Remedy

The AC power cord is not inserted firmly into the AC power adapter or the AC outlet.

Insert the power cord firmly as far as it will go.

The physical connection and communication method settings are different.

Check the communication method (LAN or SERIAL) in CONGIF >CONTROL I/F in the RM menu. Change the communication method setting if it is different to the physical connection method. • “VISCA over IP (LAN) connection” (page 14) • “Configuring a serial connection” (page 23) Note LAN connection and serial connection cannot be used at the same time.

Operation is not possible while the control panel buttons and LEDs are blinking.

(Serial connection) The communication baud rate setting of the camera and the unit differ.

Set the baud rate to the same setting as the camera (9,600 bps or 38,400 bps) (page 23).

(Serial connection) The VISCA RS-422 connection is not correctly made.

Check the connection of the VISCA RS-422 connectors and the RS-422 cable (page 21 and 22).

(LAN connection) The GROUP number differs.

Select the correct GROUP number of the target camera (page 27).

(LAN connection) There is a mismatch between the MAC address and IP address information of the connected camera and the registered camera table.

Delete the camera table contents using AUTO IP SETUP >CLEAR TABLE in the RM menu, and build the camera table again (page 19).

A menu other than the FUNCTION menu, OPERATION menu, RM menu, or top menu is displayed.

Select the RM menu top menu.

The remote controller is set to update mode.

Set MAINTENANCE >UPDATE MODE to OFF in the RM menu (page 25).

The group number is not Not using a LAN connection. displayed, and the GROUP LEFT and GROUP RIGHT buttons cannot be operated. CAMERA 8 to 10 buttons cannot be selected.

These functions are enabled for a LAN connection only.

50

Dimensions

Specifications

Top

Input/output connectors

306 (12 1/8)

Control input/output VISCA RS-422 connector: RJ-45 LAN connector: RJ-45, 10BASE-T/ 100BASE-TX auto sensing GPI I/O: D-sub 15-pin TALLY IN/ CONTACT OUT Control signal format (RS-422 communication) 9,600 bps/38,400 bps Power connector JEITA type 4 (12 V DC)

General specifications Unit: mm (in)

Input voltage 12 V DC (10.8 V to 13.2 V) Current consumption 0.6 A max. (All lamps lit) Operating temperature 0 °C to 40 °C (32 °F to 104 °F) Storage temperature –20 °C to +60 °C (–4 °F to 140 °F) Dimensions 306 mm × 159.3 mm × 224.1 mm (12 1/8 in × 6 3/8 in × 8 7/8 in) (width / height / depth) (excluding protrusions) Mass Approx. 2.4 kg (5 lb 4.7 oz)

58.9 (2 3/8)

159.3 (6 3/8)

Front

1.8 (3/32)

180 (7 1/8)

Optional accessories AC adapter (AC-UES1230 series)

63 (2 1/2) Unit: mm (in)

Side

For details about the recommended AC adapter, contact your Sony sales representative.

3 222 (8 /4)

Design and specifications are subject to change without notice.

1 ight) 180 (7 /8) (left/r

224.1 (8 7/8)

) 11 8.5 ( /32) (front/back

27

21 ( /32) (left/right)

Unit: mm (in)

51

Rear

Pin assignments VISCA RS-422 output connector 1

63 (2 1/2)

Pin

180 (7 1/8)

1 Unit: mm (in)

8

Signal name RXD OUT–

2

RXD OUT+

3

TXD OUT–

4

GND

5

GND

6

TXD OUT+

7

No connection

8

No connection

GPI I/O connector (D-sub 15-pin, female) 1

8

9

15

Pin

52

Signal name

1

TALLY IN/CONTACT OUT 1

2

TALLY IN/CONTACT OUT 2

3

TALLY IN/CONTACT OUT 3

4

TALLY IN/CONTACT OUT 4

5

TALLY IN/CONTACT OUT 5

6

TALLY IN/CONTACT OUT 6

7

TALLY IN/CONTACT OUT 7

8

TALLY IN/CONTACT OUT 8

9

TALLY IN/CONTACT OUT 9

10

TALLY IN/CONTACT OUT 10

11

No connection

12

No connection

13

GND

14

GND

15

GND

TALLY/CONTACT connector input connection example

TALLY/CONTACT connector output connection example

Switch or relay connection RM-IP500 External device

External device Recommended voltage: 5 V (Maximum 24 V)

RM-IP500 +3.3 V 10 kΩ

Maximum load current: 100 mA

Load

4.7 Ω

47 kΩ

47 kΩ

Open-collector connection

Input waveform of TALLY/CONTACT connector

External device

RM-IP500 +3.3 V Approx. 2.7 V (open voltage)

10 kΩ

90% 0.2 V or less (closed voltage)

47 kΩ

10% Tfall

Tlow

Trise

Thigh

Tfall, Trise: within 5 msec 47 kΩ

Tlow, Thigh: 33 msec or more

In Expand mode, the following can also be applied: Tally in 1

Tally in 2

Tally in 7

Thold Tskew

Tskew

Tskew: within 0.5 msec Thold: 33 msec or more

53

License This software partially supports component uIP. Therefore the following license conditions apply. Copyright (c) 2001-2006, Adam Dunkels and the Swedish Institute of Computer Science All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE AUTHOR `AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

54

Sony Corporation

Loading...

Remote Controller - Sony.net

4-696-257-11(1) Remote Controller Operating Instructions Before operating the unit, please read this manual thoroughly and retain it for future refe...

3MB Sizes 114 Downloads 8 Views

Recommend Documents

Universal Remote Controller URC22B-6A
Granada(UK) 9. Grundig 10. Grunpy 2. Hallmark 1. Hanseatic 6. Hantarex 1. Harvard 1. Hemmerrnann 1. Hinair 5. Hitachi .

PID CONTROLLER TUNING REMOTE EXPERIMENT WITH - UFSM
Abstract: This work demonstrates a fully operational laboratory with theoretical learning backup and guidance. The Moddl

Konig KN-URC20B Remote Controller manual
... remote control Télécommande universelle T elecomando universale Mando a distancia universal Controlo remoto univer

Manual Vivanco Ur 12 Remote Controller - WordPress.com
CONTROLLER User's Manual VIVANCO UNIVERSAL CONTROLLER UR 12 - CODES. Manual (GB) Instructions ... codes voor de SAB. Dis

VRV, VRF Air Conditioning System, VRV Wired Remote Controller
First launched in Japan in 1982, the daikin VRV system has been embraced by the world markets for over three decades. No

UR 89 Universal Controller (GB) Instructions Vivanco UR 89 remote
El LED da luz intermitente. – Excepto con ocasión de buscar códigos TV, también puede presionar brevemente la tecla

CONTROLLER
As principais atividades do cargo são: - Elaboração de informação Financeira e de Gestão a apresentar aos órgãos

Remote Controlled Car Remote Controlled - ProSoft Technology
Page 18. Cementing India's. Infrastructure. UltraTech cement and. ProSoft radios. Page 16. Remote. Controlled. Car. Remo

Remote Jobs at Fleetio: A Remote Company
There are now 5 Remote Jobs at Fleetio tagged Javascript, AngularJS and Senior such as Senior Angular/Ionic Developer, C

LeadDesk Remote Listener 1.0 Download - LeadDesk Remote
Aug 29, 2017 - No specific info about version 1.0. Please visit the main page of LeadDesk Remote Listener on Software In